超声波清洗机的换能器的故障问题都有哪些?

来源:http://www.sinokohl.com/ 时间: 2021-07-21 浏览次数: 0

超声波清洗机的换能器的故障问题都有哪些?在使用仪器前,需要了解换能器超声波清洗机的重要配件之一,在使用过程种,只有保证换能器正常工作了,才能拥有更好的清洗效果。一旦在使用过程中换能器出现故障,会影响整个超声波清洗机的清洗功能,那么常见的换能器会出现的故障有什么呢?
What are the problems with the transducer of ultrasonic cleaning machine? Before using the instrument, it is necessary to understand one of the important accessories of the transducer ultrasonic cleaning machine. In the process of use, only when the transducer works normally can it have better cleaning effect. Once the transducer fails in the process of use, it will affect the cleaning function of the whole ultrasonic cleaning machine. What are the common failures of the transducer?
超声波清洗机常见故障一:换能器常见故障之受潮
Common faults of ultrasonic cleaning machine 1: common faults of transducer affected with damp
检测换能器是否受潮,只需要用兆欧表检查换能器的绝缘电阻即可,如果电阻值达不到要求,那么可以肯定的是换能器受潮。方法:将整个换能器(喷塑外壳除外)放到烘箱中,以一百度左右的高温烘三个小时以上,直到用兆欧表检测时绝缘电阻能够达到要求为止。
To detect whether the transducer is damped, we only need to use a megohmmeter to check the insulation resistance of the transducer. If the resistance value does not meet the requirements, it is certain that the transducer is damped. Solution: put the whole transducer (except the plastic shell) into the oven and bake it at a high temperature of about 100 ℃ for more than three hours until the insulation resistance can meet the requirements when using the megohmmeter.
二:能器常见故障之振子打火和脱胶
2: Vibrator ignition and degumming
发现振子出现打火同时伴有陶瓷材料破碎的情况,这时会影响振动面的振动效果,不及时处理会烧坏振子。遇到这种情况应该找技术人员来分别检查下,将损坏的振子断开,以免影响到其他振子的正常使用。然后将损坏的振子返回厂家维修。
It is found that when the vibrator ignites and the ceramic material is broken, the vibration effect of the vibrating surface will be affected, and the vibrator will be burnt if it is not handled in time. In this case, we should find technical personnel to check and disconnect the damaged vibrator, so as not to affect the normal use of other vibrators. Then return the damaged vibrator to the manufacturer for repair.
三:不锈钢振动面穿孔
3: Stainless steel vibration surface perforation
如果超声波清洗剂的换能器满负荷使用时间太长有可能出现振动面穿孔的情况,这是由于振动面的不锈钢板长时间高频振动疲劳所致,好的方法是采购型号一样的振动面进行更换
If the transducer of ultrasonic cleaning agent is used at full load for a long time, the vibration surface may be perforated. This is due to the high frequency vibration fatigue of stainless steel plate on the vibration surface for a long time. A good solution is to purchase the same type of vibration surface for replacement